Air handling plant room with pleated fine filters and a HEPA filter bank

HVAC FILTERS  |  HEPA & CLEAN ROOM  |  INDUSTRIAL AIR FILTRATION

Air Filters
Clean Air, from Intake to Clean Room

A complete range of air filters and filtration systems, from G3 pre-filters to U16 ULPA filters, for commercial buildings, hospitals, pharma, electronics, automotive paint shops, power plants and heavy industry. Wateria Technovation selects, supplies, installs, tests and maintains air filtration systems across India and the Middle East.

Air Quality Audit · Filter Selection · Supply · Installation · Testing & Validation · Filter Management

THE RIGHT FILTER AT EVERY STAGE OF THE AIR STREAM

  • G3 to U16Coarse to ULPA efficiency
  • 99.995% @ MPPSH14 HEPA, scan-tested
  • Up to 450 °CHigh temperature filters
  • 12 Product FamiliesHVAC, process & industrial
  • India + UAESupply & support by Wateria

AIR FILTER RANGES

Twelve Filter Families for Every Application

From washable pre-filters on a fan coil to scan-tested ULPA filters over a semiconductor line and multi-stage intake systems on a gas turbine. We select media, efficiency class, frame and housing for your air flow, dust load, temperature and cleanliness target.

Panel pre-filter with galvanised frame and pleated synthetic media01

Coarse & Fine Pre-Filters

G3 – M5 · EN 779 / ISO Coarse

Panel and box pre-filters with synthetic, non-woven or compressed felt media, cardboard-frame pleated filters and washable nylon mesh filters. The first line of defence for AHUs, fan coils and intake louvres.

Galvanised / aluminium frames • Expanded metal support • Washable options • Flange or box type

Request Datasheet →
Inflated multi-pocket bag filters on galvanised frames02

Pocket / Bag Filters

G3 – F9 · synthetic, meltblown & fibreglass

Multi-pocket filters with welded or stitched pockets that inflate evenly for high dust holding and low pressure drop. Includes reverse-flow coalescing pockets for gas turbine intakes and pocket cubes for paint booths.

Synthetic, meltblown PP & glass-fibre media • 3–12 pockets • Carbon pocket option

Request Datasheet →
Compact V-bank fine filters with mini-pleat media packs03

ASHRAE Mini-Pleat & V-Bank Filters

M6 – F9 · deep pleat, mini-pleat & V-bank

Rigid fine filters with glass-fibre media in deep-pleat, hot-melt mini-pleat and V-bank formats. A very high media area gives long life, low energy use and moisture resistance, ideal as final filters in comfort and process HVAC.

Fire-retardant, water-resistant media • Plastic or metal frames • Header or box type

Request Datasheet →
Technician scan-testing a mini-pleat HEPA filter in a clean room04

HEPA, EPA & ULPA Filters

E10 – U16 · EN 1822 · 99.95% to 99.99995%

Absolute filters with wet-laid micro-glass or PTFE membrane media, in deep-pleat with aluminium separators, mini-pleat, V-bank and gel-seal designs. Each filter can be factory scan-tested for leak-free performance.

Deep pleat • Mini-pleat • V-bank • Gel seal & knife-edge • Scan-tested

Request Datasheet →
Activated carbon V-bank and panel air filters with carbon granules05

Activated Carbon & Gas-Phase Filters

Odour, VOC, SOx, NOx & ozone removal

Carbon V-bank, carbon pocket and carbon-impregnated panel filters that combine particle filtration with gas adsorption. Used for indoor air quality, kitchen exhausts, airports, labs and corrosion-sensitive control rooms.

Granular & powder carbon media • V-bank & panel • Dust-free design

Request Datasheet →
High temperature filters with steel frames inside an industrial oven06

High Temperature Filters

Up to 450 °C continuous · peaks up to 555 °C

Deep-pleat and mini-pleat ASHRAE and HEPA filters with metal frames and silicone-free glass-fibre media, plus glass-fibre oven filters and media. Built for curing ovens, sterilising tunnels and hot exhaust air.

Stainless / galvanised frames • Gasket or fluid seal • Oven pads & media

Request Datasheet →
Gas turbine air intake filter house at a power plant07

Gas Turbine & Compressor Air Intake Systems

Static, pulse-jet & anti-icing filter houses

Complete intake systems for gas turbines, compressors and large engines: weather hoods, inertial separators, coalescing pre-filters, static or self-cleaning pulse cartridge stages, anti-icing and silencers.

Onshore & offshore • Inertial separators • Demister pads • Silencers

Request Datasheet →
Paint spray booth with ceiling diffusion media and paint arrestors08

Paint Arrestors & Ceiling Filters

Spray booths & surface finishing

Pleated kraft-paper and multi-layer overspray collectors, glass-fibre paint stop mats, paint boxes and polyester ceiling diffusion media for automotive OEM and refinishing booths, plus wax booth pads.

Kraft & glass-fibre arrestors • Ceiling diffusion media • Pocket cubes

Request Datasheet →
Clean room with fan filter units, laminar flow bench and pass box09

Clean Room Equipment

ISO 5 – ISO 8 · pharma, healthcare & electronics

Fan filter units, HEPA terminal modules, laminar air flow benches, OT plenums, pass boxes, air showers, air curtains, biosafety cabinets, garment cabinets and sterile trolleys, with HEPA filters to suit.

FFU & terminal modules • LAF benches • Pass boxes • Air showers • OT plenums

Request Datasheet →
Commercial kitchen hood with stainless steel baffle grease filters10

Kitchen, Grease & Speciality Filters

Commercial kitchens, vehicles & appliances

Stainless steel baffle filters, grease collectors, aluminium foil mesh and metallic wire mesh filters, reticulated foam media, auto roll filters, air purifier filters and vehicle air filters.

SS / aluminium / GI • Washable • Fire-safe grease control • Auto roll for VAV

Request Datasheet →
Pulse-jet dust collector with felt filter bags and cages11

Dust Collection & Pollution Control

Filter bags, cages, cartridges & BIBO

Felt and woven filter bags with matching cages, pulse-jet cartridge systems and Bag-In / Bag-Out containment housings for handling hazardous dust safely during filter change.

Bags & cages up to 7 m • Pulse-jet cartridges • BIBO housings • Face masks

Request Datasheet →
Modular filter holding frames with HEPA housing and media rolls12

Holding Systems, Media & Fabrication

Frames, housings, rolls & pads

Universal and absolute filter holding frames, HEPA seal housings, conduit housings, filter media in rolls and pads (synthetic, glass fibre, demister) and custom light metal fabrication for filter banks.

Modular frames • Leak-free HEPA housings • Media rolls & cut pads • Custom sheet metal

Request Datasheet →

HOW STAGED FILTRATION WORKS

Each Stage Protects
the Next

Coarse → Fine → Absolute

Pre-filters catch large dust and insects so that fine filters last longer. Fine filters remove PM10 and PM2.5 to protect coils, fans and occupants. HEPA or ULPA filters at the end of the line capture sub-micron particles and microbes for clean rooms and critical areas. Getting the staging right lowers pressure drop, saves fan energy and extends the life of the most expensive filters.

Filter Grades Explained →

HVAC & CLEAN ROOM AIR

  1. 1Fresh / Return Air
  2. 2Pre-Filter
    G4
  3. 3Fine Filter
    F7 – F9
  4. 4AHU Coil & Fan
  5. 5HEPA Terminal
    H13 / H14
  6. ✓Clean Room
    ISO 5 – 8

GAS TURBINE AIR INTAKE

  1. AWeather Hood
  2. BInertial Separator / Coalescer
  3. CPre & Fine Filters
  4. DEPA / Pulse Cartridges
  5. ESilencer to Turbine

QUICK SELECTION GUIDE

Air Filter Grades at a Glance

GradeStandard & Approx. ISO 16890What It CapturesTypical Filter TypesTypical Use
G3 – G4EN 779 · ISO CoarseCoarse dust, insects, fibres (>10 µm)Panel, mesh, pleated pre-filters, rollsPre-filter for AHUs, FCUs, intakes
M5 – M6EN 779 · ePM10 50–70%Pollen, fine dust, PM10Pocket, pleated panel filtersComfort HVAC, second stage
F7 – F9EN 779 · ePM1 50–90%PM2.5, PM1, bacteria carriersPocket, ASHRAE deep / mini-pleat, V-bankFinal filter in offices, hospitals, food
E10 – E12EN 1822 · 85% – 99.5% @ MPPSSub-micron particlesEPA deep / mini-pleat, V-bankPre-HEPA, gas turbines, process air
H13 – H14EN 1822 · 99.95% – 99.995% @ MPPSBacteria, viruses on particles, 0.3 µmHEPA mini-pleat, gel seal, terminal modulesClean rooms, OTs, pharma, labs
U15 – U16EN 1822 · ≥ 99.9995% @ MPPSUltra-fine particlesULPA micro-glass or PTFE membraneSemiconductor, ISO 3 – 4 areas

EN 779 grades are shown because they are still widely used on drawings; ISO 16890 equivalents are approximate. MPPS = most penetrating particle size. Final selection depends on air flow, dust load, temperature, humidity and the required cleanliness class.

INDUSTRIES WE SERVE

Which Air Filters Each Industry Needs

A quick guide to the filter families typically used in each sector. Every site is different, so we confirm the final selection after an air quality audit.

● Typically required ○ As per application – Not typical
IndustryTypical AreasPre-FiltersPocket FiltersASHRAE & V-BankHEPA & ULPACarbonHigh TempAir IntakePaint ArrestorsClean Room Equip.Kitchen & GreaseDust Collection
Commercial & Public BuildingsOffices, malls, airports, metro●●●○●––––○–
Hotels & HospitalityRooms, lobbies, kitchens●●●–○––––●–
Hospitals & HealthcareOTs, ICUs, isolation, labs●●●●○–––●○–
PharmaceuticalsSterile, OSD and API areas●●●●○●––●–●
Electronics & Data CentresSemiconductor, PCB, server halls●●●●●–––●––
Automotive & Surface FinishingPaint shops, curing ovens●●●○○●–●––○
Food & BeverageProcessing, packing, bakeries●●●●○●○––●○
Oil, Gas & ChemicalControl rooms, compressors, turbines●●●○●○●–––●
Energy & PowerGas turbines, control rooms●●●○●–●–––○
Manufacturing & MaterialsCement, steel, textiles, plastics●●○–○○–○––●
HVAC engineer measuring filter pressure drop on an air handling unit

Why Choose Wateria Air Filters

Complete Range

Pre-filters to ULPA, housings and equipment.

Tested Quality

EN 779, ISO 16890 and EN 1822 grades.

Energy Saving

Low pressure drop media cuts fan power.

Engineered Selection

Based on air flow, dust load and class.

Testing & Validation

HEPA leak tests and clean room validation.

Filter Management

Scheduled replacement and AMC in India & UAE.

HOW WATERIA SUPPORTS YOU

From Air Quality Audit to Total Filter Management

  1. 01

    Air Quality Audit

    Air flows, dust load, existing filters and cleanliness targets.

  2. 02

    Filter Selection

    Grades, media, sizes, frames and housings for each stage.

  3. 03

    Supply & Installation

    Filters, holding frames, housings and clean room equipment.

  4. 04

    Testing & Validation

    Pressure drop checks, HEPA leak tests and particle counts.

  5. 05

    Filter Management

    Change-out schedules, spares stocking and AMC.

Need Air Filters for Your Site?

Let's specify the right filtration for every stage.

Share your filter sizes and grades, air flow, application or cleanliness class. Our team will recommend the right filters, housings or clean room equipment and send a techno-commercial offer.